![]() |
|
|
| |
Teledynes QUIKLOOK II, QL II+, and SENTRY platforms all use the same software Start and stop triggers enable unattended operation of any of the three systems Data acquisition Screens and keyboard shortcuts virtually identical to QUIKLOOK for DOS Data acquisition is integrated with the Windowsbased analysis software Monitor screen displays all input channel values in both volts and engineering units Monitor screen displays single-channel bar or line graph or pretension level / target range window Data acquisition rates up to 10,000 samples per second Plots No limit to the number of traces that can be plotted in a pane; up to 6 panes may be displayed on the screen at once Panes are independently resizeable Plot annotations available: data point values, text and footnotes Markers shown on trending plots: none, all, or currently-selected test only XY plotting Plot preference controls: color / background, maximum number of points, default title, legend style and channel unit groups Customized plots can be saved or exported in .pdf format FFT Y-axis scaling may be logarithmic or linear, and more resolution choices are available A motor power channel can be displayed without having been previously calculated using Plot Setup Test data Channel names and units may now be longer, up to 30 characters An additional unlimited comment field has been added List Edits displays all changes made to the test data The Test Data form now includes the Channel, Marker, QA, and Times & Loads Data forms via tabs for simpler operation The Channel Data tabbed form now includes channel dependencies and calculation channel equation information Analysis Average running loads, lights and stroke times Analysis of motor power phasing with sensor selfcorrection feature Dependent (calculated) channels are recalculated if the channel on which they are based is changed Calculated channels numbered 17-50 are saved with the other test data Calculated channels numbered 51-500 are temporary All traces on the screen can be zeroed at once Sensor calibration curves (linear, 2nd order, or 3rd order) are generated from a calibration test A linear, 2nd order, or 3rd order calibration may be applied to acquired data Standard and custom reports Several standard reports are now available Any client report can be replicated for use within QUIKLOOK II Self verification QUIKLOOK II automatically performs a self-check verification every time it is started |
||||||||||||
|
Home | e-mail: sales_testservices@teledyne.com Copyright © 2007 Teledyne Technologies Incorporated. All rights reserved. Teledyne Test Services 513 Mill Street Marion, MA 02738 USA |